Call Today: 817-803-4444
Coppell, Texas — Clements Electric Commercial and Residential Service
Dallas & Denton • Est. 1955

Electrician in Coppell, TX

Need an electrician in Coppell, TX? Clements Electric provides same-day residential and commercial electrical service across Coppell and Dallas County — repairs, panel upgrades, lighting, surge protection, standby generators, and EV chargers — from licensed Texas electricians (TECL #40628), 7 AM to 7 PM. 4.7★ Google rating from 520 reviews.

Prefer a written estimate? Request one

Licensed & Insured — TECL #406287:00 AM – 7:00 PM, Mon–FriVeteran-Owned · Since 1982

Commercial Electrical Contractor in Coppell

For businesses, property owners and general contractors in Coppell: tenant finish-out, service and capacity upgrades, warehouse lighting, machine wiring and controls, priced from drawings or a site walk with a written scope. Licensed Texas electrical contractor, TECL #40628.

Electrical Services in Coppell

ServiceWhat you get
Electrical repair & troubleshootingSame-day diagnosis, written flat-rate quote
Panel upgrades & replacementsCode-compliant, permit and inspection included
Whole-home surge protection$350–$850 installed, UL 1449-listed SPD
Cummins standby generatorsTypical 20kW whole-house: $13,500–$17,000 all in. Estimate only; installations vary, and a site visit determines your price.
LED & recessed lightingResidential and commercial
EV charger installationLevel 2, sized to your panel

Why Coppell Calls Clements

  • Licensed & insured: TECL #40628 · Master Electrician #214180
  • Veteran-owned, serving DFW since 1982
  • Same-day dispatch to Coppell from our Grand Prairie hub, 7 AM–7 PM
  • Written flat-rate quotes before any work begins
  • Permits and city inspections handled for you

What Panel Work Costs in Coppell

A 100-amp to 200-amp panel replacement in Coppell typically runs $2,200–$4,800 all in, including the panel, breakers, permit, inspection and labor. That is a typical range, not your price. Panel prices vary with material costs, the size of the panel and service, and how complex the job is.

JobTypical price
Straightforward swap to a single 200-amp panel (from 100 amps), all in$2,200–$4,800
Meter base, service mast or grounding workIncluded in the quote when the service entrance needs it
400-amp service, or an added 200-amp panel feeding a separate building such as a shopQuoted after an on-site load calculation

Every Coppell job gets a written flat-rate quote, or a detailed itemized one if you prefer, before work starts, and we coordinate the meter disconnect and release with Oncor Electric Delivery. How panel upgrades work

Permits & Power in Coppell

Who issues the permit

Electrical permits for work in Coppell are issued by the city, and it is the city that inspects the finished work. Requirements, fees and inspection scheduling differ from one DFW city to the next.

Clements Electric pulls the permit and schedules the inspection as part of the job. Texas Electrical Contractor TECL #40628.

Who owns the wires

Most Coppell addresses are served by Oncor Electric Delivery. Part of the city is served by CoServ Electric and Texas-New Mexico Power (TNMP) instead — utility territory does not follow city limits.

This matters on a service or panel upgrade: the utility named on your electric bill is the one that has to disconnect and then release the meter before the new service can be energized. Worth checking your bill before scheduling, and we coordinate that call either way.

Solar Panels & a Standby Generator in Coppell

If your Coppell home has grid-tied solar, the solar has to connect on the utility side of the generator’s transfer switch, between the meter and the switch, so the generator can never feed the solar inverters. We explain why in adding a standby generator to a home with solar panels. How that connection is made depends on the utility that serves your address, and more than one serves Coppell: Oncor Electric Delivery or CoServ Electric or Texas-New Mexico Power (TNMP). Check the name on your electric bill, because utility territory does not follow city limits.

Oncor Electric Delivery (delivery utility)

  • Disconnect: A visible, lockable, labeled AC disconnect is required between the Oncor meter and every source of distributed generation, within 10 feet of the meter unless special placards are used. Oncor states that molded-case breakers are not an acceptable disconnect.
  • Meter socket: The meter socket is reserved for Oncor metering. No meter collars or other devices may be installed in it or between the meter and the socket.
  • Generator and transfer switch: The generator transfer switch must be installed on the load side of the meter base, never integrated with or in series with the meter. Oncor asks installers to confirm whether the transfer switch is open or closed transition.
  • Solar approval: Solar needs an Oncor interconnection application, and Oncor treats a system as certified when it meets UL 1741 and the applicable parts of IEEE 1547.

Sources: Oncor Electric Service Guidelines (February 2025), sections 100.01.18, 500.06 and 700; Oncor Residential/Small Commercial Project Requirements (May 2025). Checked 2026-09-30.

CoServ Electric (electric cooperative)

  • Disconnect: CoServ requires a visible, lockable, labeled AC disconnect with a visible break and an external handle, on an exterior wall within 10 feet of the CoServ meter (a placard is required at the meter if it is farther), and lockable open with a cooperative lock.
  • Meter socket: CoServ's Electric Service Manual says its meter sockets are to be used exclusively for CoServ metering, and members may not double lug them.
  • Generator and transfer switch: CoServ requires an application before a standby generator is installed, requires an automatic transfer switch, and says standby generators must not export power and must use an open-transition (break-before-make) transfer switch.
  • Solar approval: Residential solar goes through CoServ's interconnection application, a $150 fee, and a review of up to 15 business days. The system may not operate until CoServ issues its permission-to-operate letter. CoServ asks whether the inverter is UL 1741 certified and requires IEEE 1547 compliance.
  • Worth confirming: CoServ's generator FAQ says it allows a GenerLink transfer switch, which mounts at the meter socket. That sits uneasily with its own meter-socket rule, so we confirm with CoServ before relying on either.
  • Not published by CoServ Electric: whether a supply-side tap between the meter and the main disconnect needs separate CoServ approval. We confirm these with the utility in writing before the job rather than assume another utility’s rule applies.

Sources: CoServ Distributed Generation Procedures and Guidelines Manual (February 2026); CoServ Electric Service Manual, section 6.2; CoServ: Requirements for Residential Emergency/Standby Generation; CoServ: Solar Installations. Checked 2026-09-30.

Texas-New Mexico Power (TNMP) (delivery utility)

  • Disconnect: TNMP requires a visible, lockable, labeled AC disconnect with an external handle between the TNMP meter and all sources of distributed generation, on an accessible exterior wall within 10 feet of the meter (placards if farther). TNMP states that molded-case breakers are not acceptable, and its list of covered equipment includes generators.
  • Meter socket: TNMP requires a company-approved meter socket, and no meter or metering equipment may be bypassed without its prior approval.
  • Generator and transfer switch: TNMP requires a transfer switch on permanently installed generators and allows open-transition (break-before-make) switches, with the application filed through its PowerClerk portal.
  • Solar approval: Solar goes through TNMP's PowerClerk portal: interconnection agreement, letter of no objection, then a notification of completion. Permission to operate comes when TNMP installs its distributed generation meter, for which TNMP lists a $227 meter change fee.
  • Not published by Texas-New Mexico Power (TNMP): whether meter collars are allowed; whether a supply-side tap needs separate TNMP approval. We confirm these with the utility in writing before the job rather than assume another utility’s rule applies.

Sources: TNMP Residential / Small Commercial Project Requirements; TNMP: Interconnecting; TNMP: Backup Generators. Checked 2026-09-30.

Frequently Asked Questions

Yes. Clements Electric runs same-day electrical service in Coppell from 7 AM to 7 PM, dispatched from our Grand Prairie hub. Call 817-803-4444 to check today's availability.

Get Your Quote — Coppell

Fast response from local Coppell electricians. No obligation.

Or have us call you back in Coppell

No obligation. We call from 817-803-4444, 7 AM to 7 PM Monday through Friday.

Licensed & Insured

Electrical Contractor TECL #40628

Veteran-Owned

Proudly serving since 1982

Same-Day Service

Mon–Fri · weekend emergencies

Need an Electrician in Coppell?

Clements Electric has served Coppell and the surrounding area since 1982. Our licensed, insured electricians are standing by for same-day service, emergency repairs, and accurate quotes.

Prefer a written estimate? Request one